2CP5-47 Transducer
The 2cp5-47 Transducer is a specialized pressure transducer from Sensata Technologies , designed exclusively for HVAC and refrigeration (HVAC/R) applications.

Product Features
sensata 2cp5-47
Ceramic Capacitive Technology
The core of the sensata 2cp5-47 is its ceramic capacitive sensing element, which ensures high stability and resistance to harsh refrigerants, offering long-term accuracy in challenging industrial environments.
Temperature Compensation
Designed for extreme conditions, the sensor operates reliably in temperatures ranging from -40°C to +135°C, ensuring data integrity whether used in sub-freezing suction lines or high-temperature discharge lines.
High Reliability Design
Equipped with overvoltage, short circuit and reverse voltage protection, strong EMC immunity and ESD protection.
Flexible Configuration
Optional gauge/absolute/sealed gauge measurement types, two connection materials and two seal materials.
Technical Specifications
2cp5-47 pressure sensor
| Parameter | Details |
|---|---|
| Product Series | Sensata 2CP5 |
| Pressure Range | 0-520 psi |
| Accuracy | ±1.5% *F.S. |
| Total Error Band | ±1.0%(-20°C~+85°C);±1.5%(-40°C~+125°C) |
| Operating Temperature | -40°C ~ +135°C |
| Supply Voltage | 4.5V~5.5V DC |
| Output Signal | 0.5V~4.5V DC(typical) |
| Response Time | 10ms |
| Overvoltage Protection | 16V DC |
| Reverse Voltage Protection | -14V DC |
| Output Load | 10K ohms typical |
| Pressure Port | 1/4″ SAE Female Flare with Deflator (7/16-20 UNF-2B) |
| Pressure Connection Material | HNBR or Neoprene options available |
| Enclosure Rating | IP65 |
Applications
sensata pressure 2cp5-47
- Discharge and Suction Pressure Monitoring: Essential for real-time monitoring of coolant state in AC systems.
- Condenser Fan Control: Facilitates automated fan speed adjustments based on head pressure.
- Compressor Oil Pressure Monitoring: Protects mechanical components by ensuring adequate lubrication levels.
- Subcooling and Superheat Calculations: Provides the precision pressure data required for high-efficiency system optimization.
- Electronic Expansion Valve (EEV) Control: Enables closed-loop control for precise refrigerant metering.
Related 2CP5 Models
sensata pressure sensors
- 2CP5-71-47
- Core Specs: Pressure range (0-750 psia), plated steel housing, EMC immunity (100 V/m, 1 MHz-512 MHz); see 2CP50-71-1 pressure sensor
- Application: Industrial environments with strong electromagnetic interference (such as factory HVAC systems) for high-pressure monitoring.
- 2CP5-71-49
- Core Specs: Pressure range (0-590 psia), plated steel housing, EMC immunity (100 V/m, 1 MHz-512 MHz); see 2CP50-71-22 pressure sensor.
- Application: Industrial environments with strong electromagnetic interference (such as factory HVAC systems) for high-pressure monitoring.
- 2CP5-71-32
- Core Specs: Absolute pressure measurement (0-750 psia), analog voltage output (0.5V-4.5V), plated steel material, cylindrical threaded housing;
- Compatibility: Suitable for high-pressure refrigeration loops (e.g., R410a, R32 refrigerants);
- Application: Industrial-grade HVAC systems (such as large centrifugal chillers) requiring high-pressure monitoring.
- 2CP5-71-66
- Core Specs: Pressure range (0-600 psia), plated steel housing, HNBR seal;
- Compatibility: Adapted to low-GWP refrigerants (e.g., R454a, R454b);
- Application: Commercial refrigeration systems (such as supermarket cascade refrigeration units) with medium-to-high pressure demands.
- 2CP5-67
- Core Specs: Full-range measurement (0-650 psia), plated steel construction, temperature-compensated design;
- Application: Heavy-duty refrigerated transport (e.g., container refrigeration units) for monitoring high-pressure refrigerant discharge lines.
- 2CP5-65-5
- Core Specs: Pressure range (0-550 psia), optimized for R134a refrigerant;
- Application: Medium-to-high pressure commercial air conditioning systems (such as rooftop packaged units for large shopping malls).
- 2CP5-50-1
- Core Specs: High burst pressure (2500 psi), pressure range (0-600 psia), plated steel material;
- Application: Industrial water-cooled chillers (e.g., York YVAA series) for monitoring compressor discharge pressure.
- 2CP5-35
- Core Specs: Pressure range (0-620 psia), compatible with R410a refrigerant, short-circuit and overvoltage protection (16 VDC);
- Protection Rating: NEMA 4X/IP65;
- Application: Outdoor HVAC equipment for compressor staging and unloading control in high-pressure loops.
Ready to Impletment in Your Application?
Our applications engineers work with you to design the optimal solution for yourspecific requirements, Get expert consultation and custom configuration support.
Request a Quote
Get a customized solution for your application!
FAQ
2cp5 Pressure Transducer
What is the difference between the 2CP5 and 2CP50 series?
The primary difference lies in the pressure range. The 2CP5 is designed for applications up to 500 psi, while the 2CP50 series is utilized for pressures above 500 psi, extending up to 750 psi
Which refrigerants are compatible with the HNBR seal?
The HNBR (Hydrogenated Nitrile) seal is compatible with R134a, R404a, R407c, R410a, and R507. If you are using R12 or R22, Neoprene seals are generally recommended.
Does the sensor require a specific mating connector?
Yes, the 2CP50-71-4 typically utilizes a Packard Metri-Pack electrical connection, designed to mate with Packard connector #12065287 for a secure, IP65-rated seal.
What pressure port and connection materials are available, and do they match standard industrial fittings?
A: The pressure port is 1/4″ SAE female flare (with deflator) + 7/16″-20 UNF-2B. Connection materials include brass (2CP5-exclusive) or plated steel — aligned with common industrial fitting standards.