Power generation boilers use fuels such as coal, oil, or natural gas to heat water and therefore produce steam, which is in turn used to drive turbine generators. The economics of power generation relies to a great extent on the efficiency of the fuel to heat conversion process and therefore the power generation industry is amongst the most advanced users of efficiency techniques based on online process analysis.

Water Quality Monitoring in Steam and Watere Analysis System

Power Plant of Steam and Water Analysis System(SWAS) is used in power plants and in those industrial processes where it is needed to CONTROL AND MONITOR WATER QUALITY. In power plants, it is needed to control the water/steam cycle characteristics in order to avoid damage to the components of the circuit as the steam turbine and the boilers.

Within the power station, the aim of water and steam control is to minimize contamination of the circuit, thereby reducing corrosion as well as cutting down the risk of the formation of harmful impurities. Therefore it is very important to control the quality of water to prevent the deposits on turbine blades by Silica (SiO2), reduce corrosion by dissolved oxygen (DO), or prevent acid corrosion by Hydrazine (N2H4). Measurement of water conductivity gives an excellent initial indication of falling water quality, analysis of Chlorine (Cl2), Ozone (O3), and Chloride (Cl) used for control of cooling water disinfecting, an indication of corrosion, and detection of cooling water leaks in the condense stage.

BOQU Solution for available parameters for both process & laboratory solutions

Water TreatmentSteam CycleCooling Water
Chloride Chlorine Chlorine Dioxide Conductivity Total Dissolved Solids (TDS) Dissolved Oxygen Hardness/Alkalinity Hydrazine/Oxygen Scavenger Oxidation-Reduction Potential Ozone pH Silica Sodium Total Organic Carbon (TOC) Turbidity Suspended Solids(TSS)Ammonia Chloride Conductivity Total Dissolved Solids (TDS) Copper Dissolved Oxygen Hydrazine/Oxygen Scavenger Hydrogen Iron Oxidation-Reduction Potential pH Phosphate Silica Sodium Total Organic Carbon (TOC)Chloride Chlorine/Oxidants Chlorine Dioxide Conductivity/Total Dissolved Solids (TDS) Copper Hardness/Alkalinity Microbiology Molybdate and Other Corrosion Inhibitors Oxidation-Reduction Potential Ozone pH Sodium Total Organic Carbon (TOC)

Recommended model

ParametersModel
pHPHG-2081X Online pH Meter
ConductivityDDG-2080X Industrial Conductivity Meter
Dissolved oxygenDissolved Oxygen Meter
SilicateGSGG-5809 Online Silicate Analyzer
PhosphateLSGG-8090 Industrial Phosphate Analyzer
SodiumDWG-5088 Online Sodium Meter
HardnessPFG-3085 Online Hardness Meter
Hydrazine(N2H4)LNG-5087 Industrial Online Hydrazine analyzer